Advanced machine integration
Monitoring and control of complex industrial machines.
SENQUIP QUAD
Monitoring and control for outdoor assets, industrial sensors and exposed machines. Designed for remote, power-constrained and environmentally demanding applications.





Key features
Dual CAN FD

Two CAN FD interfaces, plus RS232, RS485, SDI-12 and 1-Wire for flexible integration with sensors, controllers and machinery.
External Antennas

External cellular and GNSS antennas provide reliable reception and flexible antenna placement in demanding installations.
Edge Processing

Powerful onboard scripting enables local data processing, decision making and control without relying on cloud connectivity.
Satellite Ready

Ready for Starlink Direct to Cell , extending communications beyond terrestrial cellular coverage for assets operating in remote locations.
Dual can fd
cellular
satellite
solar
battery
J1939
RS485
Modbus
RS232
SDI12
1-wire
Voltage
4-20mA
Pulse
Frequency
Duty Cycle
Switch
Resistance
Reference
Accelerometer
GNSS
Bluetooth
Output
VSET
Tamper
Magnetic
Scripting
Two independent CAN FD interfaces enable simultaneous connection to multiple CAN networks or machine systems.
Global LTE Cat-1 bis connectivity provides reliable communications across a wide range of cellular networks, making ORB ideal for equipment deployed across different countries and regions.
Ready for Starlink Direct to Cell connectivity, extending communications beyond terrestrial cellular coverage to assets operating in the most remote locations.
Connect a solar panel directly to the ORB – no external regulator required. Integrated solar charging and the long-life LTO battery make it ideal for remote, off-grid installations.
The largest backup battery in the Senquip family, with 1500 mAh capacity. LTO technology delivers thousands of charge cycles, excellent temperature performance and long service life, making it ideal for solar-powered and unattended installations.
FAKRA-connected LTE and GNSS antennas provide secure, resilient connections and flexible antenna placement.
J1939 is the most common CAN-based protocol used by diesel engines and engine controllers. Senquip devices can decode standard and proprietary J1939 messages, making it easy to monitor engine performance, fuel consumption, fault codes and operating hours.
RS485 is a robust serial interface designed for long cable runs and noisy industrial environments. It is commonly used to connect sensors, PLCs, variable speed drives and other industrial equipment. Senquip supports RS485 for reliable data acquisition and control.
Modbus is one of the world’s most widely used industrial communication protocols and typically operates over RS485. Senquip typically acts as a Modbus Master, allowing it to read measurements from sensors, controllers and drives, and control compatible equipment. It can however act as a slave and pretend to be a sensor.
RS232 is a simple point-to-point serial interface found on many sensors, GPS receivers and legacy industrial devices. Senquip can capture serial data or communicate with compatible equipment for monitoring and integration.
Connect directly to SDI-12 environmental and agricultural sensors for monitoring water level, soil conditions, weather and other remote measurements.
Connect directly to 1-Wire sensors for simple, reliable monitoring of temperature and other measurements using minimal wiring.
Measure analogue voltages from sensors, battery systems and control circuits. Built-in calibration converts raw voltages into meaningful engineering units such as fuel level, pressure or temperature.
The 4–20mA current loop is the industrial standard for transmitting analogue measurements over long distances. Senquip connects directly to pressure, level, flow and many other process sensors with high accuracy and excellent noise immunity.
Count pulses from flow meters, water meters, rain gauges and other pulse-output devices. Senquip can also measure pulse frequency to calculate flow rates, speed and equipment utilisation.
Measure frequency outputs from sensors, magnetic pickups and rotating machinery. Frequency can be used to monitor speed, engine RPM, flow or any sensor that reports information as a pulse train.
Measure the percentage of time a digital signal is ON compared with its total cycle time. Duty cycle is commonly used for PWM control signals, proportional valves and electronically controlled actuators.
Monitor simple ON/OFF signals such as float switches, pressure switches, engine run signals, alarm contacts and door switches. Ideal for detecting machine state, alarms and equipment status.
Connect resistive sensors such as fuel level senders directly to the device. Senquip provides a precision excitation current and automatically calculates sensor resistance for accurate level measurement.
Generate a precision 0–10V reference output for controlling variable speed drives, proportional valves and other equipment requiring an analogue control signal. Output voltage can be adjusted locally or from a script.
The integrated three-axis accelerometer measures movement, tilt and vibration. It can detect machine operation, harsh impacts, excessive vibration and equipment orientation without additional sensors.
ntegrated GNSS provides accurate position, speed and time using GPS, Galileo, GLONASS and BeiDou satellites. Ideal for asset tracking, geofencing, utilisation monitoring and theft prevention.
Receive data wirelessly from Bluetooth Low Energy (BLE) sensors and beacons. Monitor temperature, pressure, humidity, battery status and many other parameters without additional wiring.
Each multifunction I/O can switch power, ground or configurable voltages to control relays, valves, lights and other field devices. Outputs can be operated from settings, scripts or remote commands.
VSET provides a configurable supply voltage for powering external sensors directly from the Senquip device. It is ideal for switched sensor power in low-power and solar-powered applications.
An integrated tamper switch detects when the enclosure is opened. Tamper events can generate immediate alerts, providing additional security and a record of authorised or unauthorised access.
An internal magnetic switch allows the device to wake up, enter setup mode or trigger custom functions without opening the enclosure. Simply place a magnet over the marked position on the device.
Senquip devices include an onboard JavaScript engine for local automation and custom data processing. Create application specific control logic, decode proprietary protocols and automate machines—even without network connectivity.
Technical Specification
| Feature | Description | QUAD-C3-S | QUAD-C1-G | |
|---|---|---|---|---|
| Cellular | Cellular technology | 4G LTE CAT-1bis External antenna | 4G LTE CAT-M1 External antenna | 2G, 3G, 4G CAT-1 External antenna |
| Cellular Region | Regions supported | Global | USA, Europe, Australia | Australia, Europe, Asia, Africa |
| SIM | SIM card options | Nano SIM + ESIM | micro SIM | micro SIM |
| Wi-Fi | 802.11 b/g/n, 2.4GHz | Yes Internal antenna | Yes Internal antenna | Yes Internal antenna |
| Satellite | Starlink Direct to Cell | Ready | ||
| GPS | GPS, BeiDou, Galileo and GLONASS | Yes External antenna | Yes External antenna | Yes External antenna |
| Bluetooth | Bluetooth version 4.2 | Yes | Yes | Yes |
| RS485 | Data capture, Modbus and fully scripted modes | 1 with configurable termination | 1 with configurable termination | 1 with configurable termination |
| RS232 | Data capture, Modbus and fully scripted modes | 1 | 1 | 1 |
| CAN | High speed CAN FD, no limitation on protocol support | 1 with configurable termination | 1 | 1 |
| SDI12 | SDI-12 interface | 1 | ||
| 1-Wire | 1-Wire interface | 1 | ||
| Multipurpose IO | Configurable IO channels | 5 | 5 | 5 |
| IO measurement functions | Analog, digital | 5 | 5 | 5 |
| Frequency, pulse, duty cycle | 2 | 2 | 2 | |
| Direct resistance measurement | 1 | |||
| Configurable pullup resistor | Yes | Yes | Yes | |
| Outputs | 4-20mA | 5 source and sink | 5 source and sink | 5 source and sink |
| Switch to ground | 5 | 5 | 5 | |
| Switch to Vin | 5 | 5 | 5 | |
| Voltage reference | 1 | |||
| Current reference | 1 | |||
| Accelerometer | Pitch, roll, angle, vibration, impact detection functionality. Wake from sleep. | Yes | Yes | Yes |
| Magnetic Sensor | Configurable to wake device, enter setup mode, trigger script action | Yes | Yes | Yes |
| Tamper | Inbuilt tamper detection | Tamper switch | Light sensor | Light sensor |
| Power | 10VDC to 75VDC, solar with inbuilt regulator | Yes | Yes | Yes |
| Backup Battery | Internal rechargeable backup battery technology | LTO 7.2V 1500mAh | LiPo 3.6V 1800mAh | LiPo 3.6V 1800mAh |
| Boost Supply | Continue to power external sensors when power is lost with internal supply boosted from backup battery | 5-25V | 12V | 12V |
| Edge Processing | Write and deploy JavaScript applications to manipulate data, create alerts, control devices and more | Yes | Yes | Yes |
| Configuration | Via embedded webserver, Senquip connect App, or online at the Senquip Portal | Yes | Yes | Yes |
| Third Party Endpoints | UDP, MQTT/S and HTTP/S with customisable data packet formats supported | Yes | Yes | Yes |
| Security | Secure boot, encrypted data storage and PKI-secured communications with device-specific certificates | Yes | Yes | Yes |
| Environmental | Operating temperature | -30°C to 80°C | -20°C to 80°C | -20°C to 80°C |
| Battery charge temperature range | -30°C to 80°C | 0°C to 45°C | 0°C to 45°C | |
| IP rating | IP67 | IP67 | IP67 | |
| Certification | Certifications and compliance | CE, FCC, RCM, RoHS and REACH | CE, FCC, RCM, RoHS and REACH | CE, FCC, RCM, RoHS and REACH |
| Cybersecurity | CE RED Cyber | |||
| Part Number | Senquip device ordering code | QUAD-C3-S | QUAD-C2-G | QUAD-C2-H |
Check for CAT-M availability in your region
Documentation
Full documentation available here
Browse Other Senquip Products
POPULAR QUAD Applications
Lots of companies focus on light vehicles, Senquip monitors everything else.
Dual Engines

Monitor two engines independently, combining CAN data, operating hours, fuel consumption, faults and machine status into a single connected system.
Crushers

Monitor engine and machine data, operating hours, fuel, vibration, conveyor operation and production status across multiple machine systems.
Hybrid Generators

Monitor generator, battery and power systems together, combining engine CAN data with energy storage, fuel, electrical measurements and operating status.
Drill Rigs

Combine engine, drilling and auxiliary system data to monitor operating hours, utilisation, fuel, location and drilling activity across complex machine networks.
Documentation
Brochures
Datasheets
Tech Tips
Tools
Mobile Apps
Application Notes
Application ideas
Contact us
Corporate Office
755 Hunter St,
Newcastle West, NSW 2302,
Australia
Delivery Address
Unit B, 15 Soldiers Point Road,
Soldiers Point, NSW 2317,
Australia




